Redline HVAC · HVAC · WO-24396

98

out of 100

Proof Score™

Excellent

Documentation quality for Rooftop Unit Service

Shared100% evidence completeGenerated by Jordan Pratt
Video clarity
GPS verified
Timestamp verified
Technician identified
Work order identified
Installation clearly visible
Safety equipment documented
Equipment documented
Serial numbers captured
Before/After evidence
Work explanation
Recommended follow-up included

AI recommendations

  • Documentation is complete — no additional capture required before invoicing.
Executive summary

HVAC work at 7536 Camelback Rd, Dallas, TX was completed and documented on site by Jordan Pratt. The technician captured a narrated walkthrough of the finished installation, confirmed all connections and equipment were in working order, and verified the work area was cleaned and secured before departure. All required evidence for customer approval, warranty and audit was captured.

Work completed
  • Completed Rooftop Unit Service at 7536 Camelback Rd, Dallas, TX
  • Recovered refrigerant and removed the failed unit from the curb
  • Set, sealed and secured the replacement unit to the existing curb
  • Reconnected power, controls, condensate and gas where applicable
  • Charged, started up and verified supply-return split under load
  • Work area cleaned, debris removed and site secured
  • Customer walkthrough narrated on camera for approval
Materials mentioned
  • Packaged rooftop unit
  • Curb adapter and gasket
  • Refrigerant and filter drier
  • Control wiring and whip
  • Labeling and identification tags
Equipment identified
  • Refrigerant gauges and recovery machine
  • Digital thermometer and anemometer
  • Crane or boom lift
  • Kaulii mobile capture — GPS and timestamp signed at recording
Safety observations
  • Lockout/tagout applied before any energized or pressurized work
  • PPE worn throughout — eye protection, gloves, hard hat where required
  • Work zone barricaded and signage posted
  • Area cleared and secured before departure
Issues found
  • LowCondenser fan blade shows early corrosion pitting on two blades — noted for monitoring only.
Recommended follow-up
  1. 1Schedule a follow-up inspection within 90 days.
  2. 2Add this asset to the preventative maintenance rotation.
  3. 3Share this report with the property contact for approval.
Technician statement

Alright, this is work order WO-24396. My name is Jordan Pratt with Redline HVAC. I'm at 7536 Camelback Rd, Dallas, TX for Rooftop Unit Service. I'm going to walk you through the completed work now. Here's the finished installation — you can see everything is mounted level and secured. Walking around the left side, all the connections are torqued and labeled. Here's the main equipment, and I'm getting a close-up of the nameplate so you have the model and serial on file. Safety-wise, I had lockout applied the whole time I was in the panel, PPE on, and the area was taped off. As far as the work completed, we handled the full hvac scope, tested everything, and it's reading in range. One thing I did run into was some wear on the adjacent equipment — nothing that affects today's work but worth watching. For follow-up, I'd recommend an inspection in about 90 days. Here's a final overview of the completed job, cleaned up and ready for the customer. That's it for work order WO-24396.

Evidence gallery
Supervisor review
Documentation qualityExcellent
Evidence completeness100%
Customer readyYES
Claim readyYES
Warranty readyYES
Audit readyYES
Supervisor confidenceHigh
Timeline
Recording date2026-07-29
Time10:53 AM CDT
Recording duration5m 48s
Report generated2026-07-29 · report built in 53 seconds
Work orderWO-24396
CompanyRedline HVAC

30.2433° N, 97.7633° W

7536 Camelback Rd, Dallas, TX

Timestamp verified at capture

Scan to open the live online version of this report. Included on the branded PDF.