Skip to content
Kaulii

RPT-90201

Pioneer Telecom Services · Fiber · WO-24237

74

out of 100

Proof Score™

Acceptable

Documentation quality for Aerial Fiber Splice

Ready67% evidence completeGenerated by Malik Turner
Video clarity
GPS verified
Timestamp verified
Technician identified
Work order identified
Installation clearly visible
Safety equipment documented
Equipment documented
Serial numbers captured
Before/After evidence
Work explanation
Recommended follow-up included

Missing evidence

  • Portions of the footage are motion-blurred and unusable as evidence.
  • Final installation overview missing.
  • Serial number not visible on any captured frame.
  • No follow-up recommendation was recorded.

AI recommendations

  • Re-record the unclear segments with the camera held steady for 5 seconds per shot.
  • Record a wider overview of the completed installation.
  • Capture serial number labels close enough to read.
  • Record what should happen next and show final cleanup before leaving.
Executive summary

Fiber work at 5987 Stemmons Fwy, Omaha, NE was completed and documented on site by Malik Turner. The technician captured a narrated walkthrough of the finished installation, confirmed all connections and equipment were in working order, and verified the work area was cleaned and secured before departure. A small number of evidence gaps were detected and are listed below.

Work completed
  • Completed Aerial Fiber Splice at 5987 Stemmons Fwy, Omaha, NE
  • Pulled and secured the fiber drop from the pedestal to the demarcation point
  • Fusion spliced the strands and seated them in a protected splice tray
  • OTDR tested the span end to end and recorded loss values on video
  • Labeled the drop, sealed the enclosure and restored the work area
  • Work area cleaned, debris removed and site secured
  • Customer walkthrough narrated on camera for approval
Materials mentioned
  • Single-mode drop cable
  • Fusion splice sleeves
  • Weatherproof splice enclosure
  • Cable ties and drop clamps
  • Labeling and identification tags
Equipment identified
  • Fusion splicer
  • OTDR and optical power meter
  • Fiber cleaver and cleaning kit
  • Kaulii mobile capture — GPS and timestamp signed at recording
Safety observations
  • Lockout/tagout applied before any energized or pressurized work
  • PPE worn throughout — eye protection, gloves, hard hat where required
  • Work zone barricaded and signage posted
  • Area cleared and secured before departure
Issues found
  • MediumExisting pedestal seal is degraded and allows moisture intrusion.
  • LowAccess panel hardware is worn and should be replaced at next visit.
Recommended follow-up
  1. 1Schedule a follow-up inspection within 90 days.
  2. 2Add this asset to the preventative maintenance rotation.
  3. 3Share this report with the property contact for approval.
Technician statement

Alright, this is work order WO-24237. My name is Malik Turner with Pioneer Telecom Services. I'm at 5987 Stemmons Fwy, Omaha, NE for Aerial Fiber Splice. I'm going to walk you through the completed work now. Here's the finished installation — you can see everything is mounted level and secured. Walking around the left side, all the connections are torqued and labeled. Here's the main equipment, and I'm getting a close-up of the nameplate so you have the model and serial on file. Safety-wise, I had lockout applied the whole time I was in the panel, PPE on, and the area was taped off. As far as the work completed, we handled the full fiber scope, tested everything, and it's reading in range. One thing I did run into was some wear on the adjacent equipment — nothing that affects today's work but worth watching. For follow-up, I'd recommend an inspection in about 90 days. Here's a final overview of the completed job, cleaned up and ready for the customer. That's it for work order WO-24237.

Evidence gallery
Supervisor review
Documentation qualityAcceptable
Evidence completeness67%
Customer readyNO
Claim readyNO
Warranty readyYES
Audit readyNO
Supervisor confidenceLow
Timeline
Recording date2026-06-18
Time9:32 AM CDT
Recording duration5m 27s
Report generated2026-06-18 · report built in 50 seconds
Work orderWO-24237
CompanyPioneer Telecom Services

30.2452° N, 97.7652° W

5987 Stemmons Fwy, Omaha, NE

Timestamp verified at capture