RPT-90409
Pacific Fiber Solutions · Fiber · WO-24029
71
out of 100
Proof Score™
Acceptable
Documentation quality for Aerial Fiber Splice
Missing evidence
- ⚠ Portions of the footage are motion-blurred and unusable as evidence.
- ⚠ Technician never stated their name on the recording.
- ⚠ Work order number was not spoken or shown on camera.
- ⚠ Safety PPE not shown at any point in the walkthrough.
- ⚠ Serial number not visible on any captured frame.
AI recommendations
- “Re-record the unclear segments with the camera held steady for 5 seconds per shot.”
- “State your full name and role in the first 10 seconds.”
- “Say the work order number out loud at the start of the walkthrough.”
- “Show PPE and lockout/tagout before opening any panel.”
- “Capture serial number labels close enough to read.”
Fiber work at 9017 Industrial Blvd, Sacramento, CA was completed and documented on site by Jamal Whitfield. The technician captured a narrated walkthrough of the finished installation, confirmed all connections and equipment were in working order, and verified the work area was cleaned and secured before departure. A small number of evidence gaps were detected and are listed below.
- Completed Aerial Fiber Splice at 9017 Industrial Blvd, Sacramento, CA
- Pulled and secured the fiber drop from the pedestal to the demarcation point
- Fusion spliced the strands and seated them in a protected splice tray
- OTDR tested the span end to end and recorded loss values on video
- Labeled the drop, sealed the enclosure and restored the work area
- Work area cleaned, debris removed and site secured
- Customer walkthrough narrated on camera for approval
- Single-mode drop cable
- Fusion splice sleeves
- Weatherproof splice enclosure
- Cable ties and drop clamps
- Labeling and identification tags
- Fusion splicer
- OTDR and optical power meter
- Fiber cleaver and cleaning kit
- Kaulii mobile capture — GPS and timestamp signed at recording
- Lockout/tagout applied before any energized or pressurized work
- PPE worn throughout — eye protection, gloves, hard hat where required
- Work zone barricaded and signage posted
- Area cleared and secured before departure
- LowExisting pedestal seal is degraded and allows moisture intrusion — noted for monitoring only.
- 1Schedule a follow-up inspection within 90 days.
- 2Add this asset to the preventative maintenance rotation.
- 3Share this report with the property contact for approval.
Alright, this is work order WO-24029. My name is Jamal Whitfield with Pacific Fiber Solutions. I'm at 9017 Industrial Blvd, Sacramento, CA for Aerial Fiber Splice. I'm going to walk you through the completed work now. Here's the finished installation — you can see everything is mounted level and secured. Walking around the left side, all the connections are torqued and labeled. Here's the main equipment, and I'm getting a close-up of the nameplate so you have the model and serial on file. Safety-wise, I had lockout applied the whole time I was in the panel, PPE on, and the area was taped off. As far as the work completed, we handled the full fiber scope, tested everything, and it's reading in range. One thing I did run into was some wear on the adjacent equipment — nothing that affects today's work but worth watching. For follow-up, I'd recommend an inspection in about 90 days. Here's a final overview of the completed job, cleaned up and ready for the customer. That's it for work order WO-24029.