Skip to content
Kaulii

RPT-90565

Blue Peak Plumbing · Plumbing · WO-24311

77

out of 100

Proof Score™

Acceptable

Documentation quality for Backflow Preventer Install

Shared58% evidence completeGenerated by Kevin Nguyen
Video clarity
GPS verified
Timestamp verified
Technician identified
Work order identified
Installation clearly visible
Safety equipment documented
Equipment documented
Serial numbers captured
Before/After evidence
Work explanation
Recommended follow-up included

Missing evidence

  • GPS unavailable — location could not be confirmed from the capture device.
  • No close-up of the primary installed equipment.
  • Serial number not visible on any captured frame.
  • Narration does not explain what work was actually completed.
  • No follow-up recommendation was recorded.

AI recommendations

  • Enable location services on the capture device before recording.
  • Retake a close-up of the installed equipment nameplate.
  • Capture serial number labels close enough to read.
  • Add 20 seconds of plain-language narration describing the completed work.
  • Record what should happen next and show final cleanup before leaving.
Executive summary

Plumbing work at 3490 Maple Grove Ln, Boise, ID was completed and documented on site by Kevin Nguyen. The technician captured a narrated walkthrough of the finished installation, confirmed all connections and equipment were in working order, and verified the work area was cleaned and secured before departure. A small number of evidence gaps were detected and are listed below.

Work completed
  • Completed Backflow Preventer Install at 3490 Maple Grove Ln, Boise, ID
  • Isolated the affected branch and verified no residual pressure
  • Removed the failed assembly and installed the replacement to code
  • Pressure tested the repair and checked for leaks at all joints
  • Restored service and confirmed flow and drainage at the fixtures
  • Work area cleaned, debris removed and site secured
  • Customer walkthrough narrated on camera for approval
Materials mentioned
  • Backflow preventer assembly
  • Copper and PVC fittings
  • Pipe dope and thread sealant
  • Hangers and supports
  • Labeling and identification tags
Equipment identified
  • Press tool and jaws
  • Pressure test kit
  • Drain inspection camera
  • Kaulii mobile capture — GPS and timestamp signed at recording
Safety observations
  • Lockout/tagout applied before any energized or pressurized work
  • PPE worn throughout — eye protection, gloves, hard hat where required
  • Work zone barricaded and signage posted
  • Area cleared and secured before departure
Issues found
  • MediumShutoff valve upstream of the repair is stiff and should be replaced.
  • LowAccess panel hardware is worn and should be replaced at next visit.
Recommended follow-up
  1. 1Schedule a follow-up inspection within 90 days.
  2. 2Add this asset to the preventative maintenance rotation.
  3. 3Share this report with the property contact for approval.
Technician statement

Alright, this is work order WO-24311. My name is Kevin Nguyen with Blue Peak Plumbing. I'm at 3490 Maple Grove Ln, Boise, ID for Backflow Preventer Install. I'm going to walk you through the completed work now. Here's the finished installation — you can see everything is mounted level and secured. Walking around the left side, all the connections are torqued and labeled. Here's the main equipment, and I'm getting a close-up of the nameplate so you have the model and serial on file. Safety-wise, I had lockout applied the whole time I was in the panel, PPE on, and the area was taped off. As far as the work completed, we handled the full plumbing scope, tested everything, and it's reading in range. One thing I did run into was some wear on the adjacent equipment — nothing that affects today's work but worth watching. For follow-up, I'd recommend an inspection in about 90 days. Here's a final overview of the completed job, cleaned up and ready for the customer. That's it for work order WO-24311.

Evidence gallery
Supervisor review
Documentation qualityAcceptable
Evidence completeness58%
Customer readyYES
Claim readyNO
Warranty readyYES
Audit readyNO
Supervisor confidenceModerate
Timeline
Recording date2026-03-16
Time11:34 AM CDT
Recording duration4m 29s
Report generated2026-03-16 · report built in 52 seconds
Work orderWO-24311
CompanyBlue Peak Plumbing

30.2474° N, 97.7674° W

3490 Maple Grove Ln, Boise, ID

Timestamp verified at capture

Scan to open the live online version of this report. Included on the branded PDF.